Friday, February 28, 2014

Surging 10hp tecumseh in coleman generator

Surging 10hp Tecumseh in Coleman generator.


I have a 5000 watt Coleman generator from 1999 with a 10hp Tecumseh engine. It starts up easlily, but RPM and power surges at any load. My son has now added to the problem. He made changes to the governor spring position and its adjustment bolt. There are 6 notches where the spring can sit, and the bolt has been moved in and out. Anyone know what would cause the surging and what are the correct governor spring settings and make adjustments to the bolt? has the carb been removed? If so it may need a static governor adjustment A shop did work on the carb 2 years ago. It has sat ever since, without testing it. I went to use it for the first time since getting it from the shop and it started right up, but would constantly surge. I checked the filter, which was fine, and then went looking for the old manual. I never found it, and while I was looking for it is when the son decided to play with the governor spring. It still runs, but I can tell the speed is slower, and still surging. Static governor adjustment? How do I get info on doing this? Never mind, I looked it up. It also said likely cause is partly blocked carb. I will clean, then try Static governor adjustment, and then check for correct AC output. remember that when you get it running smooth you need to adjust the speed so it's putting out 60 cycles, normally that's printed somewhere as a certain rpm like 3600. I used a kill-o-watt meter to adjust mine as it gives the AC cycles output Yes, my RShack volt meter has cycles display. Thanks for your help 38racing. You giving the name to the adjustment needed was what I needed. I looked for hours without luck until you gave me what to look for. link below for anyone interested. Understanding and Adjusting your Governor on a small engine Originally Posted by bradwyle Yes, my RShack volt meter has cycles display. Thanks for your help 38racing. You giving the name to the adjustment needed was what I needed. I looked for hours without luck until you gave me what to look for. link below for anyone interested. Understanding and Adjusting your Governor on a small engine Most inexpensive volt meters won't give cycles.








Related Posts:




  • Tecumseh hmsk80 surging

    Tecumseh HMSK80 surgingWhen I started up my snow blower yesterday to test after new friction disk and belts, it started surging fairly dramatically. At a rate of about once per second, it accelera...


  • Tecumseh 3 hp engine h3035387s running rich

    Tecumseh 3 HP engine (h30-35387s) running richI have a Troy-Bilt Tuffy rototiller with a Tecumseh 3 hp engine that I bought used. The carburetor was very clogged; I cleaned it and tried to run it....


  • Trigas convert kit on briggs stratton generator

    Tri-Gas Convert Kit on Briggs Stratton GeneratorHello all. I am looking at adding the conversion kit for Tri-gas from: Generator Conversion Kits to Propane and Natural Gas. and their system works...


  • Tecumseh lev 120 carbgoverner

    Tecumseh lev 120: carb/governerToro lawnmower (2003) started dying not under load - could keep going by pushing bulb slightly. Pulled carb and cleaned. Reinstalled carb. Starts, but only putt, put...


  • Toro snowblower surging ccr 2000e

    Toro Snowblower surging- CCR 2000eI have a Toro CCR 2000 (model number 38185) that is surging. It is a single stage 2 cycle model. I understand from a search that I most likely need to clean and r...